A minimum of 4 in.
Slope roof wall connection detail no overhang.
Kick out flashing for stucco 2019 detail.
Above we show a feeble attempt at flashing and counter flashing at the roof wall intersection of a low slope roof.
2 details for conventional wood frame construction.
To prevent heat buildup this house was constructed without eave overhangs which also eliminates soffit vents.
Here you can view and download individual floor and roof details for your use.
No air leaks from underneath no problems.
Weep screed for stucco 2020 detail.
Read me first sma guide details caveat.
There is also no gutter in the detail so you will be effectively routing rain down your wall.
Wall and roof fram ing where floor and roof trusses are used and accommodates 24 inch spacing of studs where wind loads.
Wall to roof deck flashing 2020 detail.
Figure 7a shows a continuously reinforced cast in place concrete rake beam along the top of the gable end wall.
Martin and jon are right that a roof overhang is the best way to protect the siding.
Installed a new fully adhered membrane to the top of the old board sheathing prior to adding all that rigid insulation.
Sill pan for nail flange windows 2020.
Roof edge detail overhang extended to hide the thickness of the over roofing rigid insulation.
The beam is formed over uncut block in courses successively shortened to match the slope of the roof.
No roof leaks no problems.
102 mm is needed from the highest projected corner of block to the top of the beam.
Alternatively you can download a free viewer by visiting this link and downloading the dwg trueview application.
For maximum protection against fire construct walls using type x gypsum wallboard covered with a thick layer of stucco cement a roof of fire resistant shingles with bird stops at the eaves little or no overhang and no soffit vents.
The details on this site are recommended for all i joists.
The concealed barrier assembly 2016 detail.
Figure 8 24c shows a corbel eaves detail with no soffit and with the junction between rafter and ceiling tie taken beyond the outside of the wall.
Gable end wall overhangs.
If you don t have autocad you will need to sign up for a free account and use autodesk viewer a web based applications.
I can understand not wanting one with a flat roof but the sloped roof without overhang i never understood.
Roof wall flashing detail specifications snafus.
This particular detail would impose certain structural problems for all types of roof construction and may require a blocked heel or additional top chord should trussed rafters be specified.
There is no good way to make that last.
Second floor overhang of exterior wall joists at right angles to supporting.
3 larger than opening 2 x 10 insulation baffle attic access hatch 22 1 2 x 30 opening i i sht.